What is the reason for the decrease in resistivity during the operation of reverse osmosis EDI pure water equipment?

Author:chunke Click: Time:2021-08-30 00:00:00 From:Guangzhou chunke environmental technology co.,ltd


Guangzhou Chunke Water Treatment Network News: The resistivity decreases during the operation of reverse osmosis EDI pure water equipment. The resistivity is another indicator of the conductivity of water. The unit is MΩ·cm, which means that two flat electrodes with a cross-sectional area of 1cm2 are in The resistance value in water when the distance is 1cm. Resistivity has a reciprocal relationship with conductivity. In order to improve the characterization accuracy of water conductivity, when the conductivity is higher than 1μS/cm, it can be characterized by conductivity, and when the conductivity is less than 1μS/cm, it can be characterized by resistivity. The reason for the decrease in resistivity is related to the pollution of the influent water quality, pressure, flow, voltage, and influent water quality.



1.Reverse osmosis equipment effluent is unqualified (including conductivity, hardness, variable metal, etc.)


If the raw water has high salt content, it is recommended to use bipolar RO reverse osmosis equipment as pre-demineralization, and its electrical conductivity is kept at 1~3μS/cm. CO2 removal. The pH deviates too much from neutral. Use pH adjustment to make the pH value of the EDI inlet water at 7-8. In the process of contact with air, the carbon dioxide gas dissolved in the high-purity water causes the conductivity to rise. Therefore, the conductivity of high-purity water should be tested under online airtight conditions.




2、There is a problem with the current control of the EDI system


The working current increases, and the quality of the produced water keeps getting better. However, if the current is increased after increasing to the highest point, the amount of H+ and OH- ions produced by water ionization is too much. Except for the regeneration of resin, a large number of surplus ions act as current-carrying ions for conduction, and at the same time, due to the movement process of a large number of current-carrying ions Accumulation and clogging occurred during the process, and even reverse diffusion occurred, resulting in a decline in the quality of the produced water.



3、PH change


The EDI system has a high CO2 content in the inlet water. If the CO2 content is greater than 10ppm, the EDI system cannot produce high-purity water.


4、Iron pollution


The iron pollution in the operation of the EDI system is the main reason for the progressive decrease in the resistance of the water produced. If ordinary steel pipes are used in the raw water and pretreatment system without internal anti-corrosion treatment, the iron content in the system will increase. After the iron is corroded, most of it will be dissolved in the water in the form of Fe(OH)2 and will be further oxidized. It becomes Fe(OH)3. Fe(OH)2 is a colloidal substance, and Fe(OH)3 is in a suspended state. The resin has a strong affinity for iron, and after being adsorbed by the resin, it will cause an irreversible reaction. In the anion and cation exchange water treatment, the anion and cation beds will be regenerated or cleaned to remove most of the iron in the resin. However, in the operation of EDI equipment, there is no regeneration and cleaning, and trace iron elements in the water will adhere to the yin and yang resins and the yin and yang films. Iron has strong electrical conductivity, and before it reacts with the cationic resin, it is moved to the cationic membrane by the EDI module near the cationic water. Simple iron ions are easy to penetrate, while the iron compounds in the jelly are not easy to penetrate the cation membrane, and are adsorbed on the surface of the cation membrane, contaminating the cation and cation membranes, and ultimately lead to the decline of the working performance of the EDI module and the poor quality of water produced. The resistance value shows a progressive decrease.


5.Organic pollution


Reverse osmosis edi pure water equipment is polluted by organic colloids in the water. Reverse osmosis can only remove organic colloids with a relative molecular weight greater than 200. Those with a molecular weight below 200 enter the EDI system. This part of the low-molecular-weight substance is adsorbed on the mesh of the skeleton and the surface of the anion and cation membrane by the anion and cation exchange resin in the module, which hinders the replacement reaction of anion and cation and the penetration rate of the ions in the water through the anion and cation membranes. , Thereby causing the performance of EDI to decline, and the resistivity of the produced water declines.



What is the reason for the decrease in resistivity during the operation of reverse osmosis EDI pure water equipment?
Guangzhou Chunke Water Treatment Network News: The resistivity decreases during the operation of reverse osmosis EDI pure water equipment. The resistivity is another indicator of the conductivity of w
Long by picture save/share
0
图片展示

GUANGZHOU CHUNKE ENVIRONMENTAL TECHNOLOGY CO.,LTD

CONTACT US

Tel:139 2612 2290

Tel:86-020-3605 2778    36052728   86314618

Fax:86-020-2289 5083        

E-mail:510440  

Address:No.8,suyuanzhuang,qinghu village,junhe street, baiyun district, guangzhou,china

      

           

               Scan the code to contact           

Copyright @ VillaGrandis All Rights Reserved  ICP备案号180006020号-3

Service Center
热线电话
86-020-36052778
上班时间
周一到周五
E-mail地址
123456@qq.com
Qrcode
扫码联系
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了